It seems that you are using a browser that does not support today's standard for displaying web content. This may cause some parts of the website to not function properly. We recommend that you update your browser or download one that meets today's standard.

Update

Cookie settings

Cookies are small browser files that allow us to temporarily store information about your device and you, as a user, exclusively while you are browsing the LICON website. These files help us obtain information about traffic and user behavior, based on which we continuously improve the website.

Back to list

KORAWALL Direct WVD (24 V DC)

connection via adapter to 24 V DC

Wall-mounted convector with forced convection, autonomous control and 24 V DC connection.
The KORAWALL Direct WVD wall-mounted 24 V DC convector is a powerful fan heater suitable for low-temperature heating. The convector is equipped with a specially designed Al/Cu heat exchanger in RAL 9005 lacquer and a set of low-energy quiet fans. The convector is equipped with an autonomous control with an integrated keypad, allowing fans to be controlled directly on the unit. Connection to the mains is via a 24 V DC socket adapter. The convector achieves high heat outputs even at low-temperature gradients, and in non-condensing zones it can also be used for aftercooling, which is particularly advantageous in the summer months. The convector is well suited for a range of building types from new builds, private houses, office buildings to refurbishments and wherever the heat source is a heat pump, solar system or condensing boiler.                    

                                                          heat pump

  • Heating
  • Light cooling
  • Forced convection
  • Heat pump synergy
KORAWALL  Direct  WVD Wall-mounted convector with forced convection, autonomous control and 24V DC connection
Height 450 mm
Width 110 mm
Length 600, 750, 1 000, 1 250, 1 500, 1 750, 2 000 mm
Heat output from 190 to 8 960 W
Cooling output up to 1 419 W
Exchanger height 240 mm
Exchanger width 60 mm
Max. operating pressure 1,2 MPa
Max. operating temperature 90 °C
Surface temperature 40 °C According to inlet water temperature
Connection thread internal G ½"
Hydraulic connection bottom (right-side or left-side)
infoThe unit is designed for cooling in the non-condensation zone only, i.e. above the dew-point temperature. The unit is not equipped with condensate drainage.

Tepelné výkony [W] při t1/t2/ti = při 75/65/20 ˚C (Δt=50) a 55/45/20 ˚C (Δt=30)/EN 442


Heat output

Depth 450 / Width 110
Length Speed level Heat output Electrical input / 24 V DC Acoustic pressure [dB(A)] Acoustic performance [dB(A)]
600 0 1,4 - -
600 1 2,1 23,2 31,2
600 2 2,6 27,9 35,9
600 3 3,4 32,3 40,3
600 4 4,4 36,8 44,8
600 5 5,7 40,8 48,8
750 0 1,4 - -
750 1 2,4 24,9 32,9
750 2 2,8 29,6 37,6
750 3 3,8 34,0 42,0
750 4 4,4 38,3 46,3
750 5 6,2 42,3 50,3
1000 0 1,4 - -
1000 1 2,6 26,3 34,3
1000 2 3,5 30,9 38,9
1000 3 4,9 35,2 43,2
1000 4 7,1 39,8 47,8
1000 5 10,3 43,9 51,9
1250 0 1,4 - -
1250 1 2,8 26,7 34,7
1250 2 3,8 31,3 39,3
1250 3 5,8 35,3 43,3
1250 4 8,3 40,5 48,5
1250 5 12,4 44,9 52,9
1500 0 1,4 - -
1500 1 3,0 28,7 36,7
1500 2 4,1 33,3 41,3
1500 3 6,3 37,4 45,4
1500 4 9,2 42,2 50,2
1500 5 13,2 46,4 54,4
1750 0 1,4 - -
1750 1 3,9 30,2 38,2
1750 2 5,5 34,7 42,7
1750 3 9,1 38,9 46,9
1750 4 11,8 43,5 51,5
1750 5 17,1 47,6 55,6
2000 0 1,4 - -
2000 1 5,3 30,5 38,5
2000 2 5,7 35,0 43,0
2000 3 8,4 39,0 47,0
2000 4 13,1 43,9 51,9
2000 5 18,4 48,2 56,2

Cooling output

Depth 450 / Width 110
Length Speed level Cooling output Electrical input / 24 V DC Acoustic pressure [dB(A)] Acoustic performance [dB(A)]
600 0 1,4 - -
600 1 2,1 23,2 31,2
600 2 2,6 27,9 35,9
600 3 3,4 32,3 40,3
600 4 4,4 36,8 44,8
600 5 5,7 40,8 48,8
750 0 1,4 - -
750 1 2,4 24,9 32,9
750 2 2,8 29,6 37,6
750 3 3,8 34,0 42,0
750 4 4,4 38,3 46,3
750 5 6,2 42,3 50,3
1000 0 1,4 - -
1000 1 2,6 26,3 34,3
1000 2 3,5 30,9 38,9
1000 3 4,9 35,2 43,2
1000 4 7,1 39,8 47,8
1000 5 10,3 43,9 51,9
1250 0 1,4 - -
1250 1 2,8 26,7 34,7
1250 2 3,8 31,3 39,3
1250 3 5,8 35,3 43,3
1250 4 8,3 40,5 48,5
1250 5 12,4 44,9 52,9
1500 0 1,4 - -
1500 1 3,0 28,7 36,7
1500 2 4,1 33,3 41,3
1500 3 6,3 37,4 45,4
1500 4 9,2 42,2 50,2
1500 5 13,2 46,4 54,4
1750 0 1,4 - -
1750 1 3,9 30,2 38,2
1750 2 5,5 34,7 42,7
1750 3 9,1 38,9 46,9
1750 4 11,8 43,5 51,5
1750 5 17,1 47,6 55,6
2000 0 1,4 - -
2000 1 5,3 30,5 38,5
2000 2 5,7 35,0 43,0
2000 3 8,4 39,0 47,0
2000 4 13,1 43,9 51,9
2000 5 18,4 48,2 56,2
Convector composition

HPS
KORAWALL WVD rozpad

Standard contents

 

1 galvanized steel RAL 9016 white or RAL 9005 matt black casing
 safety cover grille, punched into the casing 
3 electronic control panel with keypad in the colour of the casing (white, black)
4  230 V AC/24 V DC power supply (adapter)
5 weight-bearing part for anchoring the unit on the wall in the colour of the casing
6 Al/Cu heat exchanger lacquered in black RAL 9005 with low water content, bleed valve and uniquely shaped fins for higher heat output
a set of  24 V DC tangential low-energy EC fan assembly
8  dust filter
* ambient temperature sensor and water temperature sensor located on the heat exchanger
* installation instructions, installation template
* durable packaging
 
Optional accessories
9 LM straight / corner connection control valve
10 thermostatic head heating/cooling
* casing finish according to RAL colour chart with control keypad in silver
 
 
 
 
 
info We recommend equipping the convector with the LM regulation valve with a higher flow rate.
 
 
Power control composition

                        displej WVD regulace WVD

1 control touchpad                                                                                                                                
2 touchpad board
3 connecting cable
4 control unit
5 temp sensor (water)
6 temp sensor (room)
7 fan control cable
8 supply connector
9 230 V AC / 24 V DC power supply (adapter)
KORAWALL  Direct WVD (24VDC)   height 450 mm / widht 110 mm
           KORAWALL bokorys   WVO_nárysHPS
Measurements shown in mm.
CONVECTOR ASSEMBLY KORAWALL Direct  (WVD)  

Anchoring diagram
 

WK_montáž
Construction part
  • We recommend placing the wall-mounted unit on the perimeter wall, 100 mm above the floor.
  • We recommend equipping the convector with the LM regulation valve with a higher flow rate.
  • The water inlet must always be connected to the pipe leading to the upper part of the convector and also attach the LM regulation fitting.
  • The heat exchanger and casing must be well protected against contamination. Heating units must be regularly serviced; heat exchangers and fans cleaned.
  • The unit is installed on a wall using the rear weight-bearing part. We recommend checking the correct positioning of the heat exchanger with fittings and the casing prior to connecting the heat exchanger to the heating system.
  • KORAWALL Direct VWD is to be used with a thermostatic head for heating and cooling
  • Do not forget to install the power supply cable near the unit installation site.
  • The convector is equipped with an autonomous control with an integrated keypad, allowing fans to be controlled directly on the unit.
  • Connection to the mains is via a 24 V DC socket adapter.
info   The unit is designed for cooling in the non-condensation zone only, i.e. above the dew-point temperature. The unit is not equipped with condensate drainage.

ORDERING CODES

Example order code: WVD-150/45/11-V5SPSP-10-RT

KORAWALL Direct WVD wall-mounted convector with forced convection, autonomous control, length 150 cm, height 45 cm, width 11 cm, the color of casing including weight-bearing part for mounting – white RAL 9016, bottom right connection with 230 V AC/24 V DC power supply (adapter).

KORAWALL
Ventilator
Type
 
Length/Height/Width [cm]
 
Exchanger
type
Exchanger
colour
Casing
material
Grille
type
Connection
type
Connection
side
 
Colour
code
 
Regulation
W
V
D
-
150/45/11
-
V
5
S
P
S
P
-
10
-
RT
 
 
Direct
 
 
 
reversible
black
RAL 9005
steel
perforated
bottom
P - right
L - left
 
10 RAL 9016
** RAL - Code 
39 RAL 9005
99 other RAL colour
 
 
standard

Contact us

For more information, do not hesitate to contact us

By submitting the form, you agree to the processing of personal data.