It seems that you are using a browser that does not support today's standard for displaying web content. This may cause some parts of the website to not function properly. We recommend that you update your browser or download one that meets today's standard.

Update

Cookie settings

Cookies are small browser files that allow us to temporarily store information about your device and you, as a user, exclusively while you are browsing the LICON website. These files help us obtain information about traffic and user behavior, based on which we continuously improve the website.

Back to list

KORAWALL Pool-V  WVP

suitable for humid environments

KORAWALL Pool-V WVP wall-mounted convector is an efficient, energy-saving forced-convection heating unit and has a light cooling function designed for humid environments. The KORAWALL Pool-V WVP casing is made of AISI 316 stainless steel sheet metal. It is equipped with a heat exchanger and a set of high-performance, low-energy fans. Our wall-mounted units achieve high heating efficiency, even at low-temperature gradients. Convectors with forced convection are ideal for installation situations with heat pumps, solar-energy systems, condensing boilers, or as an additional heat source for underfloor heating. They have the advantage of being a source of pleasant heat during the seasonal transition periods of the year. If needed, they can provide a rapid ambient temperature increase. Their light-cooling ability offers an additional option in summer. Wall-mounted convectors with fans can be operated via BMS. Due to their construction and surface finish, the KORAWALL Pool-V WVP convectors are ideal for any space with high air humidity levels (except for salt water pools and other sea-watter environments).



                                                                                                                heat pump

  • Heating
  • Light cooling
  • Forced convection
  • Pool solution
KORAWALL Pool-V is a custom-made unit. Delivery lead times and prices are provided upon request.
KORAWALL  Pool-V WVP AISI 316 stainless steel sheet metal
Height 450 mm
Width 110 mm
Length 600, 750, 1 000, 1 250, 1 500, 1 750, 2 000 mm
Heat output from 190 to 8 960 W
Cooling output up to 1 419 W
Exchanger height 240 mm
Exchanger width 60 mm
Max. operating pressure 1,2 MPa
Max. operating temperature 90 °C
Surface temperature 40 °C According to inlet water temperature
Connection thread internal G ½"
Hydraulic connection bottom (right-side or left-side)
info   The unit is designed for cooling in the non-condensation zone only, i.e. above the dew-point temperature. The unit is not equipped with condensate drainage.

Tepelné výkony [W] při t1/t2/ti = při 75/65/20 ˚C (Δt=50) a 55/45/20 ˚C (Δt=30)/EN 442


Heat output

Depth 450 / Width 110
Length Speed level Heat output Electrical input / 24 V DC Acoustic pressure [dB(A)] Acoustic performance [dB(A)]
600 0 0 - -
600 1 2 23,2 31,2
600 2 3 32,3 40,3
600 3 6 40,8 48,8
750 0 0 - -
750 1 2 24,9 32,9
750 2 3 34 42
750 3 7 42,3 50,3
1000 0 0 - -
1000 1 3 26,3 34,3
1000 2 4 35,2 43,2
1000 3 10 43,9 51,9
1250 0 0 - -
1250 1 3 26,7 34,7
1250 2 5 35,3 43,3
1250 3 11 44,9 52,9
1500 0 0 - -
1500 1 4 28,7 36,7
1500 2 8 37,4 45,4
1500 3 19 46,4 54,4
1750 0 0 - -
1750 1 5 30,2 38,2
1750 2 9 38,9 46,9
1750 3 22 47,6 55,6
2000 0 0 - -
2000 1 5 30,5 38,5
2000 2 10 39 47
2000 3 23 48,2 56,2

Cooling output

Depth 450 / Width 110
Length Speed level Cooling output Electrical input / 24 V DC Acoustic pressure [dB(A)] Acoustic performance [dB(A)]
600 0 0 - -
600 1 2 23,2 31,2
600 2 3 32,3 40,3
600 3 6 40,8 48,8
750 0 0 - -
750 1 2 24,9 32,9
750 2 3 34 42
750 3 7 42,3 50,3
1000 0 0 - -
1000 1 3 26,3 34,3
1000 2 4 35,2 43,2
1000 3 10 43,9 51,9
1250 0 0 - -
1250 1 3 26,7 34,7
1250 2 5 35,3 43,3
1250 3 11 44,9 52,9
1500 0 0 - -
1500 1 4 28,7 36,7
1500 2 8 37,4 45,4
1500 3 19 46,4 54,4
1750 0 0 - -
1750 1 5 30,2 38,2
1750 2 9 38,9 46,9
1750 3 22 47,6 55,6
2000 0 0 - -
2000 1 5 30,5 38,5
2000 2 10 39 47
2000 3 23 48,2 56,2
Convector composition

HPS

KORAWALL-WVO-rozklad

Standard contents
1 safety cover grille, punched into the casing
2 convector casing made of AISI 316 stainless steel, lacquered in white RAL 9016
3 Al/Cu heat exchanger lacquered in black RAL 9005 with low water content, bleed valve and uniquely shaped fins for higher heat output
4 weight-bearing part for anchoring the unit on the wall in the colour of the casing
5 a set of low-energy EC fans 24 V DC with terminal block and regulator (FCR BOX)
6 dust filter
* installation instructions, durable packaging
 
Optional accessories
7 LM thermostatic and control valve
 thermoelectric actuator
 
* further RAL lacquers for casings available
SIEMENS RDG 260T, RDG 260KN or RAB 21-DC room thermostats 
* QAA32 room temperature sensor
* SIEMENS IRA 211 remote control 
* 24 V DC power supply
* R-Box
 
 
 
 
info We recommend equipping the convector with the LM regulation valve with a higher flow rate.
 
info Regulation elements are  not included in the standard delivery package and must be ordered separately. Regulation elements are identical for all forced-convection products (OC system).
 KORAWALL Pool-V   height 450 mm / width 110 mm

KORAWALL bokorysWVO_nárysHPS

Measurements shown in mm.
info  KORAWALL Pool-V is a custom-made unit. Delivery lead times and prices are provided upon request.
CONVECTOR ASSEMBLY KORAWALL Pool-V  (WVP) 

 Anchoring diagram

WK_montáž
Construction part
  • We recommend placing the wall-mounted unit on the perimeter wall, 100 mm above the floor.
  • We recommend equipping the convector with the LM regulation valve with a higher flow rate.
  • The water inlet must always be connected to the pipe leading to the upper part of the convector and also attach the LM regulation fitting.
  • The heat exchanger and casing must be well protected against contamination. Heating units must be regularly serviced; heat exchangers and fans cleaned.
  • The unit is installed on a wall using the rear weight-bearing part. We recommend checking the correct positioning of the heat exchanger with fittings and the casing prior to connecting the heat exchanger to the heating system.
  • The regulation is identical for KORAFLEX FV trench heaters and KORALINE LV freestanding convectors.
  • We recommend equipping the KORAWALL WVO and WVP with a thermo-electric actuator.
  • Do not forget to install the power supply cable near the unit installation site.HPS
KORAWALL Pool-V is a custom-made unit. Delivery lead times and prices are provided upon request.
info  The unit is designed for cooling in the non-condensation zone only, i.e. above the dew-point temperature. The unit is not equipped with condensate drainage.   
 

ORDER CODE

Example order code: WVP-150/45/11-V5RPSP-10-RT

KORAWALL  Pool-V WVP wall-mounted convector, length 150 cm, height 45 cm, width 11 cm, sheet metal steel casing white RAL 9016, bottom right connection with standard regulation.
KORAWALL
Ventilator
Type
 
Length/Height/Width [cm]
 
Exchanger
type
Exchanger
colour
Casing
material
Grille
type
Connection
type
Connection
side
 
Colour
code
 
Regulation
W
V
P
-
150/45/11
-
V
5
R
P
S
P
-
10
-
RT
 
 
Pool-V
 
 
 
reversible
black
RAL 9005
stainless
perforated
bottom
P - right
L - left
 
10 RAL 9016
** RAL - Code 
99 other RAL colour
 
24 V DC
regulation

Contact us

For more information, do not hesitate to contact us

By submitting the form, you agree to the processing of personal data.