FORCED CONVECTION
NATURAL CONVECTION – REGULATION and ACCESSORIES
Regulation of the heating or cooling medium flow forms a central role in the correct control of convector heating output. Correct selection of regulation elements guarantees a comfortable ambient temperature and contributes to heating cost minimalization. Fans and thermoelectric actuators are powered by 24 V DC and the fan speed is operated by 0-10V control voltage.
KORAFLEX FVO, FVE, FVP, F2V and F4V
KORALINE OLOC
KORAWALL WVO or WVP
Regulation is designed for all model lines with natural convection:
Outside temperature varies continuously during the heating period. Regulation elements are installed to the heating system to meet your desired ambient temperature and to eliminate the negative impact of outside temperature changes. Thanks to well designed regulation the KORAFLEX, KORALINE, KORAWALL model lines achieve optimal heating efficiency and considerable financial savings.
Standard contents | Optional accessories |
|
|
Installation must be carried out in accordance with valid regulations and safety procedures! The manufacturer cannot be held liable for any defects, damages and injuries caused by improper installation.
RAB 21-DC or RDG 160T thermostat function description
Trench heater output is controlled by fan speed and the flow of heating / cooling medium through the exchanger. The control voltage is 24 V. The RAB 21 DC or RDG 160T Siemens thermostats control the heating medium valve with a thermoelectric actuator, and in addition control fan speed with a control voltage of 0–10V DC. Fan speed may be controlled automatically by the thermostat, or manually in three speed settings. Speed rating is set at a control signal size of 7 V. Fans start rotating when the temperature of the heating medium exceeds 37 °C. For cooling trench heaters it is recommended to use a second temperature sensor, actuated when the temperature drops below 15 °C. Temperature sensors are available as optional accessories.
Function description with BMS (Building Management System)
The BMS central control system may be used to control trench heaters. One BMS control output directly controls the opening / closing of valves and the other 0–10 V DC output controls fan speed. Rated heat output of trench heaters is achieved at 7 V DC. Valves and fans are supplied with 24 V DC.
Using the KNX system, trench heaters may be controlled with the RDG 260KN thermostat. The thermostat communicates with the KNX system, which transmits and receives data for the trench heater.
Information on individual model lines
KORAFLEX Pool-V FVP
For KORAFLEX Pool-V humid environment trench heaters, the standard control system description applies. The difference lies in placing the FCR-BOX in a pattress box with a higher degree of protection. The fan is equipped with stainless steel casing and its electronics are protected against splashing water. For this model we recommend using a temperature sensor that monitors the temperature in the pool area. The sensor is designed for RDG 160T thermostats. The trench heater is not designed to be permanently flooded with pool water. Please familiarise yourself thoroughly with the warranty conditions and conditions of use.
KORAFLEX Energy FVE
It is powered by 230V AC mains voltage. The switched-mode power supply is situated inside the convector and converts mains voltage to 24 V DC. Fan speed is controlled by 0–10 V DC controlled voltage either from the BMS or the thermostat. Electrical installation design must be carried out by a suitably qualified person and must comply with relevant regulations. Installation and maintenance of the electrical installation must be carried out by a qualified electrical technician. Prior to commissioning, an inspection and testing of the electrical installation must be carried out in accordance with ČSN 33 1500. KORAFLEX Energy FVE convectors are powered with 230V alternating current mains electricity. Therefore the electric branch must be equipped with a residual current device with a tripping current of 30 mA. These trench heaters are to be used solely in dry environments, and only for heating.
KORAWALL Optimal-V (WVO) and Pool-V (WVP)
Regulation elements are identical for all forced-convection products (OC system). We recommend equipping the convector with the LM regulation valve with a higher flow rate.
ACCESSORIES
Lockshieldoptional accessory
• straight or elbow • order code: |
| Thermostatic valveoptional accessory KORAFLEX FV, KORALINE OLOC,
• elbow or straight • order code: straight thermostatic valve: REG-TVS |
|
Brass elbowoptional accessory • ½"×½" 90° without rim • order code: REG-E90
|
| Flexible connecting hoseoptional accessory • stainless steel mesh • order code (10 cm): REG-F10 • order code (12 cm): REG-F12 • order code (30 cm): REG-F3 |
|
DC power supply 60 W, 100 W, 150 W, 240 W and 480W optional accessory KORAWALL WVO and WVP • switch-mode DC power supply • order code: REG-PS60, REG-PS100, REG-PS150, REG-PS240, REG-PS480
|
We recommend the output of the power supply is at least 20% more than the resulting sum |
Thermoelectric actuator TEP 24optional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • reset time: 4 min. • supply voltage: 24 V DC • order code (2.5 m cable): REG-TEP24-250 |
| Junction boxoptional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • embedded in wall (60 W, 100 W and 150 W) • order code: REG-IB |
|
R-Box 2017optional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • combined with the power supply it creates the control voltage for the fan • for use with thermostat with supply voltage of • order code: REG-RBOX17 |
| NTC temperature sensoroptional accessory KORAFLEX FV, KORALINE OLOC, •temperature sensor situated on the exchanger Temperature sensor NTC is delivered separately to the trench heater. |
|
SIEMENS RDG 160T elctronic room termostat with LCD displayoptional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • for 2 and 4 pipe heating systems |
| SIEMENS RAB 21-DC Manual room thermostatoptional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • for 2-pipe heating systems
For correct operation, RDG160T or RDDG260KN thermostats must be set according to the LICON |
|
SIEMENS RDG 260KN electronic room thermostat with LCD displayoptional accessory KORAWALL WVO and WVP order code: REG-RDG260KN |
| |
|
For correct operation, RDG160T or RDDG260KN thermostats must be set according to the LICON instructions included in the thermostat package. The thermostat is supplied pre-set for heating in a 2-pipe system.
QAA32 external room temperature sensoroptional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • for measuring temperature in heating |
| SIEMENS IRA 211 infrared remote controloptional accessory KORAFLEX FV, KORALINE OLOC, KORAWALL WVO and WVP, • infrared remote control for RDG 160T |
|
CONVECTOR WIRING DIAGRAMS | |
1. For SIEMENS RDG 160T or SIEMENS RAB21-DC thermostat-controlled | KORAFLEX FVO, F2V Heating or cooling KORAWALL WVO and WVP - Heating or cooling |
2. For BMS controlled trench heaters - Heating or cooling | KORAFLEX FVO, F2V Heating or cooling KORAWALL WVO and WVP - Heating or cooling |
3. For SIEMENS RDG 160T or RAB21-DC thermostat controlled from more than one source | KORAFLEX FVO, F2V Heating or cooling from more than one source KORAWALL WVO and WVP - Heating or cooling |
4. FVE trench heater basic wiring diagrams | KORAFLEX FVE |
KORAFLEX FVE | |
6. For SIEMENS RDG 160T thermostat controlled F4V trench heaters | KORAFLEX F4V - Heating and cooling |
Further wiring diagrams can be found at www.licon.cz, or upon request. The RDG 160T thermostat is pre-set for 2-pipe heating systems. For alternative methods of heating, the SIEMANS RDG 160T or RAB21-DC thermostats must be set according to the instructions enclosed, or see Download
1. For SIEMENS RDG 160T or SIEMENS RAB21-DC thermostat-controlled
KORAFLEX FVO, F2V Heating or cooling
KORALINE OLOC - Heating
KORAWALL WVO and WVP - Heating or cooling
2. For BMS controlled trench heaters - Heating or cooling
KORAFLEX FVO, F2V Heating or cooling
KORALINE OLOC - Heating
KORAWALL WVO and WVP - Heating or cooling
3. For SIEMENS RDG 160T or RAB21-DC thermostat controlled from more than one source
KORAFLEX FVO, F2V Heating or cooling from more than one source
KORALINE OLOC -Heating from more than one source
KORAWALL WVO and WVP - Heating or cooling
4. FVE trench heater basic wiring diagrams
5. FVE trench heater with SIEMENS RDG 160T or RAB21-DC thermostat controlled trench heater basic wiring diagrams
6. For SIEMENS RDG 160T thermostat controlled F4V trench heaters
Heating and cooling
Further wiring diagrams can be found at www.licon.cz, or upon request. The RDG 160T thermostat is pre-set for 2-pipe heating systems. For alternative methods of heating, the SIEMANS RDG 160T or RAB21-DC thermostats must be set according to the instructions enclosed, or see Downloads.