Floor convectors with forced convection Licon PKOC 7/28                                                                FV 7_28 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design

stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)

width including the U/F type frame (mm) 284U/314F
floor case width (mm) 247
grid width (mm) 272
max. adjustable height (H max. mm) 67–94
case depth (mm) 67
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 25
exchanger width (mm) 150
exchanger effective length (mm) L - 370
fans impeller diameter (mm) 30
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 8/16                                                                FV 8_16 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 164U/194F
floor case width (mm) 127
grid width (mm) 152
max. adjustable height (H max. mm) 85–110
case depth (mm) 85
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 50
exchanger effective length (mm) L - 400
fans impeller diameter (mm) 30
connection to the heating system 2× G 1/2" inner
case material

galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 8/28                                                             FV 8_28 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 284U/314F
floor case width (mm) 235
grid width (mm) 272
max. adjustable height (H max. mm) 80–107
case depth (mm) 80
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 120
exchanger effective length (mm) L - 350
fans impeller diameter (mm) 30
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 9/28                                                           FV 9_28 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 284U/314F
floor case width (mm) 235
grid width (mm) 272
max. adjustable height (H max. mm) 95 -122
case depth (mm) 95
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 120
exchanger effective length (mm) L - 350
fans impeller diameter (mm) 40
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 11/20                                                             FV 11_20 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 204U/234F
floor case width (mm) 173
grid width (mm) 192
max. adjustable height (H max. mm) 108 -132
case depth (mm) 108
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 75
exchanger width (mm) 75
exchanger effective length (mm) L - 400
fans impeller diameter (mm) 40
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 11/28 (the best selling type)                 FV 11_28 BOK                                                                                                       

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 284U/314F
floor case width (mm) 235
grid width (mm) 272
max. adjustable height (H max. mm) 115 -142
case depth (mm) 115
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 120
exchanger effective length (mm) L - 350
fans impeller diameter (mm) 40
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 11/34                                                          FV 11_34 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 344U/374F
floor case width (mm) 295
grid width (mm) 332
max. adjustable height (H max. mm) 115 -142
case depth (mm) 115
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 180
exchanger effective length (mm) L - 350
fans impeller diameter (mm) 40
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304

Floor convectors with forced convection Licon PKOC 11/42                                                          FV 11_42 BOK

Version Economic black coated zinc galvanised steel case, heat exchanger without any surface finish
Version Exclusive * custom-made design black coated zinc galvanised steel case, black coated exchanger
Version Inox * custom-made design stainless steel unpainted case AISI 304, unpainted exchanger (for dry environment only)
width including the U/F type frame (mm) 424U/454F
floor case width (mm) 375
grid width (mm) 412
max. adjustable height (H max. mm) 115 -142
case depth (mm) 115
length (L mm) 800 up to 2 800 (at 400 mm steps)
exchanger height (mm) 50
exchanger width (mm) 240
exchanger effective length (mm) L - 350
fans impeller diameter (mm) 40
connection to the heating system 2× G 1/2" inner
case material galv. steel, stainless steel AISI 304
Total length cm tem.expo.   80       120       160       200       240       280    
Speed switch position     Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3
Noisiness – acoustic pressure 1m dB(A)   0 13,2 23 31,1 0 13,4 23,1 31,6 0 13,8 23,7 31,8 0 14,7 26 32,8 0 15 26,5 33 0 15,1 26,7 33,1
Power input: W/V     3/13,5       5,5/13,5       7,5/13,5       10/13,5       13/13,5       15/13,5    
Heat output t1°C                                                  
PKOC 7/28 75/65/20 m=1,04 - 391 546 671 - 764 1065 1310 - 1137 1585 1948 - 1510 2104 2587 - 1883 2624 3226 - 2255 3144 3865
PKOC 8/16 75/65/20 m=1,05 - 201 250 300 - 411 513 615 - 626 782 937 - 788 983 1179 - 1003 1252 1501 - 1213 1515 1816
PKOC 8/28 75/65/20 m=1,1159 138 351 415 601 200 662 785 1136 229 971 1154 1670 302 1285 1523 2204 356 1597 1892 2739 410 1909 2261 3273
                                                     
Total length cm tem.expo.   80       120       160       200       240       280    
Speed switch position     Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3 Off 1 2 3
Noisiness – acoustic pressure 1m
dB(A)   0 16,1 23,6 30,5 0 16,4 21,1 30,9 0 16,7 24,4 31,1 0 17,2 25 31,4 0 17,4 25,1 31,7 0 17,7 25,3 31,7
Power input: W/V     5,5/13,5       11/13,5       12/13,5       20/13,5       22,5/13,5       23,5/13,5    
Heat output t1°C                                                  
PKOC 9/28 75/65/20 m=1,0996 145 467 627 783 210 881 1184 1479 263 1296 1741 2175 318 1711 2298 2871 374 2126 2856 3567 430 2541 3413 4263
PKOC 11/20 75/65/20 m=0,994 74 542 696 850 142 1037 1332 1627 211 1544 1983 2422 281 2053 2636 3220 350 2558 3285 4013 419 3063 3934 4806
PKOC 11/28  75/65/20 m=1,1 166 538 710 875 298 1016 1340 1653 430 1494 1971 2341 562 1972 2602 3209 694 2450 3233 3987 826 2928 3864 4765
PKOC 11/34 75/65/20 m=1,1 160 715 915 1116 302 1350 1729 2109 444 1985 2543 3101 586 2620 3357 4093 728 3255 4171 5086 870 3891 4984 6078
PKOC 11/42 75/65/20 m=1,1 221 1010 1294 1578 417 1907 2444 2981 613 2805 3595 4384 809 3703 4745 5787 1005 4600 5895 7190 1201 5498 7045 8593

Correction factor kt for a variant

temperature difference Δt (K)

 

 to download

                                                 

Standard delivery contains

  • zinc galvanized steel case, paint finish RAL 9005 – black
  • AI/Cu heat exchanger with low water content, air vent and uniquely shaped lamellas for a higher heat output
  •  group of low-energy fans
  • connecting terminal (F Box)
  • exchanger temperature switch
  • side covering metal sheets in the case colour
  • aluminium decor frame, U profile, surface finish silver eloxal coat
  • fixing anchors for fastening the convector to the floor
  • a pair of stainless steel flexible hoses for easy connection to the heating system; chipboard cover plate protecting the heat exchanger from dust and dirt on building site; 25 mm height adjustment screws to compensate for the floor unevenness
  • the unit is packed in a durable packaging and contains an installation manual

Optional accessories

  • stainless steel case finish AISI 304 (Inox) for dry environment
  • colour of the anodized Al frame – natural aluminium, light and dark bronze in the F profile or light or dark bronze in the U profile,
  • black coated heat exchanger (Exclusive finish)
  • shut off valves, thermostatic valve head and an actuator
  • covering plate with increased rigidity
  • case with noise-absorbing foil (reduction of noisiness by 1 to 3 dB)

Profiles of aluminium frames

 
Standard design – U frame

               U RÁMEČEK                                U rámeček

Standard PK design contains silver U profile. Profile colour is equal with grid colour, for other colours.

Selectable version – F frame

   F RÁMEČEK               F rámeček

When the selectable frame F is ordered, it is attached separately to convector (not installed on convector). Frame colours are identical with aluminium grid colours.

PKOC 7/28 

FV 7_28 BOK

 

FV 7_28 PUD

The floor convector with fan PKOC 7/28 can be equipped only with Aluminium cover
grid in various versions (silver, light or dark bronze).
ATTENTION The cover grid in versions stainless or wood cannot be used!

PKOC 8/16 

FV 8_16 BOK

FV 8_16 PUD

* For all manufactured lengths of PKOC 8/16 the average distance for the connection is 180 mm.
*In case of floor convector PKOC 8/16 the linear floor grid could not be manufactured as a standard product. Previous consultation is necessary and if possible the convector case is adapted.

PKOC 8/28

FV 8_28 BOK 

FV 8_28 PUD

In case of floor convector PKOC 8/28 the linear floor grid could not be manufactured as a standard product. Previous consultation is necessary and if possible the convector case is adapted.

PKOC 9/28

FV 8_28 BOK

FV 9_28 PUD

In case of floor convector PKOC 9/28 the linear floor grid could not be manufactured as a standard product. Previous consultation is necessary and if possible the convector case is adapted.

PKOC 11/20FV 11_20 BOK

FV 11_20 PUD

In case of floor convector PKOC 11/20 the linear floor grid could not be manufactured as a standard product. Previous consultation is necessary and if possible the convector case is adapted.

PKOC 11/28

FV 11_28 BOKFV 11_28 PUD

PKOC 11/34

FV 11_34 BOK

FV 11_34 PUD

PKOC 11/42

FV 11_42 BOK

FV 11_42 PUD

Convector installation – construction part Licon PKOC

Convector installation – construction recommendations Several general principles must be fulfilled to ensure proper functioning of the convector.

• A properly installed element has the exchanger located further away from the window.
• It is recommended to use the standard stainless-steel hoses with stainless-steel jacketing which always form a part of the delivery (unless recommended otherwise) for interconnecting the exchanger and the distributing pipeline. In practice they provide a better access under the heat exchanger without having to dismantle the heating system, e.g. during cleaning.
• We recommend connecting the heating system with the use of stop valves and a thermostatic valve.
• Always connect the supply of the heat-carrying medium to the heat exchanger's pipe that is further away from the fan. In case of the 34 cm width the OR-J3 heat exchanger is used; the heatcarrying medium enters through one pipe and leaves through another one.
• The PKWOC exchanger is a four pipe unit; one circuit feeds the heating circuit and the other one the cooling circuit.
• Properly installed convector is laid horizontally with the convector's case edges intact and not bent to ensure correct function of the walkable grid and the bleeding of the exchanger possible.
• Correctly installed convector's decorative frame is at the floor level with a margin of +2 mm.
• We recommend to keep the cover plate on the convector for the entire duration of the building work to prevent any dirt falling inside the convector. The standard plate is not walkable, but a plate with increased load bearing capacity can be ordered.
• The fans set is held down to the convector's case using magnets. In case of the stainless steel version the set of fans will be mounted using dry zips. This system allows you to remove the fans from the convector during the installation to avoid their damage or soiling, etc. They can be easily taken out for cleaning also during standard operation.
•The floor convector must be firmly set in the floor. The setting screws are only used for horizontal levelling of the convector case.
• Before concreting the convector must be fixed to the floor using anchoring screws that will prevent vertical shifting of the convector during subsequent pouring of concrete. When the concrete is poured the convector can be loaded vertically. During concreting the convector must be cross-braced to prevent deformation of the case. When pouring other material (e. g. anhydride) seal thoroughly all openings of the convector to prevent it from flooding.
• The convector's PKBOC setting screw consists of a flag used as a ground anchor. This type does not contain anchors.
• We recommend the fixing and sound proof insulation to be done in such a way that will allow a thin concrete to be poured to the convector's bottom and its sides. Optimal noise reduction is achieved by direct embedding of the convector in concrete.
• Installing the fan convector in free space can result in increased noise, therefore we recommend to order a case with noise absorbing foil.
• Installation into double layer floors is described later.
• Cooled convectors (PKIOC, PKWOC) have built-in as standard a water (condensate) drain. During the installation do not forget to interconnect the case at the bottom of the convector with a pipeline with guaranteed gradient for wastewater or condensate removal. We recommend to equip the drain with an odour trap.
• Convectors PKBOC are intended for use in swimming pool areas. The separation barrier is used to capture water from the pool, but cannot serve as the standard pool water overflow. This part is always placed closer to the pool. The heating part with the exchanger and fans must be always further away from the pool. The convector is provided with drainage holes in each corner, 2×. Installation, operation and maintenance of this equipment require special conditions. Please read them thoroughly on our website or in the manual.

Caution: Floor convector PKBOC with forced convection must be positioned so as to prevent even short term flooding of the section fitted with the motor and the fans.

Possibilities of convector incorporation by floor types

  1. Installation by embedding in concrete
  2. Installation in low double floor
  3. Installation in raised double floor

Dimensions of the mounting holes

Weights and water volumes

Type 7/28 8/16 8/28 9/28 11/20 11/28 11/34 11/42
steel kg/linear meter 7,06 5,38 7,3 8,5 6,53 9 11,2 12
stainless steel kg/1 linear meter 7,05 5,3 7,1 8,3 6,4 9 11 12
l/1 linear meter 0,4 0,22 0,4 0,4 0,5 0,4 0,6 0,8